Tuesday, December 4, 2007 at 9:20 AM |
To verify whether an HBA is connected to a fabric or not:

# /usr/sbin/luxadm -e port

Found path to 4 HBA ports

/devices/pci@1e,600000/SUNW,qlc@3/fp@0,0:devctl CONNECTED
/devices/pci@1e,600000/SUNW,qlc@3,1/fp@0,0:devctl NOT CONNECTED
/devices/pci@1e,600000/SUNW,qlc@4/fp@0,0:devctl CONNECTED
/devices/pci@1e,600000/SUNW,qlc@4,1/fp@0,0:devctl NOT CONNECTED



Your SAN administrator will ask for the WWNs for Zoning. Here are some steps I use to get that information:

# prtconf -vp | grep wwn
port-wwn: 210000e0.8b1d8d7d
node-wwn: 200000e0.8b1d8d7d
port-wwn: 210100e0.8b3d8d7d
node-wwn: 200000e0.8b3d8d7d
port-wwn: 210000e0.8b1eaeb0
node-wwn: 200000e0.8b1eaeb0
port-wwn: 210100e0.8b3eaeb0
node-wwn: 200000e0.8b3eaeb0


Or you may use fcinfo, if installed.

# fcinfo hba-port
HBA Port WWN: 210000e08b8600c8
OS Device Name: /dev/cfg/c11
Manufacturer: QLogic Corp.
Model: 375-3108-xx
Type: N-port
State: online
Supported Speeds: 1Gb 2Gb
Current Speed: 2Gb
Node WWN: 200000e08b8600c8
HBA Port WWN: 210100e08ba600c8
OS Device Name: /dev/cfg/c12
Manufacturer: QLogic Corp.
Model: 375-3108-xx
Type: N-port
State: online
Supported Speeds: 1Gb 2Gb
Current Speed: 2Gb
Node WWN: 200100e08ba600c8
HBA Port WWN: 210000e08b86a1cc
OS Device Name: /dev/cfg/c5
Manufacturer: QLogic Corp.
Model: 375-3108-xx
Type: N-port
State: online
Supported Speeds: 1Gb 2Gb
Current Speed: 2Gb
Node WWN: 200000e08b86a1cc
HBA Port WWN: 210100e08ba6a1cc
OS Device Name: /dev/cfg/c6
Manufacturer: QLogic Corp.
Model: 375-3108-xx
Type: N-port
State: online
Supported Speeds: 1Gb 2Gb
Current Speed: 2Gb
Node WWN: 200100e08ba6a1cc



Here are some commands you can use for QLogic Adapters:

# modinfo | grep qlc
76 7ba9e000 cdff8 282 1 qlc (SunFC Qlogic FCA v20060630-2.16)

# prtdiag | grep qlc
pci 66 PCI5 SUNW,qlc-pci1077,2312 (scsi-+
okay /ssm@0,0/pci@18,600000/SUNW,qlc@1
pci 66 PCI5 SUNW,qlc-pci1077,2312 (scsi-+
okay /ssm@0,0/pci@18,600000/SUNW,qlc@1,1
pci 33 PCI2 SUNW,qlc-pci1077,2312 (scsi-+
okay /ssm@0,0/pci@19,700000/SUNW,qlc@1
pci 33 PCI2 SUNW,qlc-pci1077,2312 (scsi-+
okay /ssm@0,0/pci@19,700000/SUNW,qlc@1,1

# luxadm qlgc

Found Path to 4 FC100/P, ISP2200, ISP23xx Devices

Opening Device: /devices/ssm@0,0/pci@19,700000/SUNW,qlc@1,1/fp@0,0:devctl
Detected FCode Version: ISP2312 Host Adapter Driver: 1.14.09 03/08/04

Opening Device: /devices/ssm@0,0/pci@19,700000/SUNW,qlc@1/fp@0,0:devctl
Detected FCode Version: ISP2312 Host Adapter Driver: 1.14.09 03/08/04

Opening Device: /devices/ssm@0,0/pci@18,600000/SUNW,qlc@1,1/fp@0,0:devctl
Detected FCode Version: ISP2312 Host Adapter Driver: 1.14.09 03/08/04

Opening Device: /devices/ssm@0,0/pci@18,600000/SUNW,qlc@1/fp@0,0:devctl
Detected FCode Version: ISP2312 Host Adapter Driver: 1.14.09 03/08/04
Complete


# luxadm -e dump_map /devices/ssm@0,0/pci@19,700000/SUNW,qlc@1,1/fp@0,0:devctl
Pos Port_ID Hard_Addr Port WWN Node WWN Type
0 1f0112 0 5006048accab4f8d 5006048accab4f8d 0x0 (Disk device)
1 1f011f 0 5006048accab4e0d 5006048accab4e0d 0x0 (Disk device)
2 1f012e 0 5006048acc7034cd 5006048acc7034cd 0x0 (Disk device)
3 1f0135 0 5006048accb4fc0d 5006048accb4fc0d 0x0 (Disk device)
4 1f02ef 0 50060163306043b6 50060160b06043b6 0x0 (Disk device)
5 1f06ef 0 5006016b306043b6 50060160b06043b6 0x0 (Disk device)
6 1f0bef 0 5006016330604365 50060160b0604365 0x0 (Disk device)
7 1f19ef 0 5006016b30604365 50060160b0604365 0x0 (Disk device)
8 1f0e00 0 210100e08ba6a1cc 200100e08ba6a1cc 0x1f (Unknown Type,Host Bus Adapter)



# prtpicl -v
.
.
SUNW,qlc (scsi-fcp, 7f0000066b) <--- go to qLogic website to get model number
:_fru_parent (7f0000dc86H)
:DeviceID 0x1
:UnitAddress 1
:vendor-id 0x1077
:device-id 0x2312
:revision-id 0x2
:subsystem-vendor-id 0x1077
:subsystem-id 0x10a
:min-grant 0x40
:max-latency 0
:cache-line-size 0x10
:latency-timer 0x40

.
.


#### The subsystem-ID value determines the model of HBA.
#### For reference table Click Here


Configuring NEW LUNs:


spdma501:# format < /dev/null
Searching for disks...done


AVAILABLE DISK SELECTIONS:
0. c1t0d0
/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w2100000c506b2fca,0
1. c1t1d0
/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w2100000c506b39cf,0
Specify disk (enter its number):


spdma501:# cfgadm -o show_FCP_dev -al
Ap_Id Type Receptacle Occupant Condition
c1 fc-private connected configured unknown
c1::2100000c506b2fca,0 disk connected configured unknown
c1::2100000c506b39cf,0 disk connected configured unknown
c3 fc-fabric connected unconfigured unknown
c3::50060482ccaae5a3,61 disk connected unconfigured unknown
c3::50060482ccaae5a3,62 disk connected unconfigured unknown
c3::50060482ccaae5a3,63 disk connected unconfigured unknown
c3::50060482ccaae5a3,64 disk connected unconfigured unknown
c3::50060482ccaae5a3,65 disk connected unconfigured unknown
c3::50060482ccaae5a3,66 disk connected unconfigured unknown
c3::50060482ccaae5a3,67 disk connected unconfigured unknown
c3::50060482ccaae5a3,68 disk connected unconfigured unknown
c3::50060482ccaae5a3,69 disk connected unconfigured unknown
c3::50060482ccaae5a3,70 disk connected unconfigured unknown
c3::50060482ccaae5a3,71 disk connected unconfigured unknown
c3::50060482ccaae5a3,72 disk connected unconfigured unknown
c4 fc connected unconfigured unknown
c5 fc-fabric connected unconfigured unknown
c5::50060482ccaae5bc,61 disk connected unconfigured unknown
c5::50060482ccaae5bc,62 disk connected unconfigured unknown
c5::50060482ccaae5bc,63 disk connected unconfigured unknown
c5::50060482ccaae5bc,64 disk connected unconfigured unknown
c5::50060482ccaae5bc,65 disk connected unconfigured unknown
c5::50060482ccaae5bc,66 disk connected unconfigured unknown
c5::50060482ccaae5bc,67 disk connected unconfigured unknown
c5::50060482ccaae5bc,68 disk connected unconfigured unknown
c5::50060482ccaae5bc,69 disk connected unconfigured unknown
c5::50060482ccaae5bc,70 disk connected unconfigured unknown
c5::50060482ccaae5bc,71 disk connected unconfigured unknown
c5::50060482ccaae5bc,72 disk connected unconfigured unknown
c6 fc connected unconfigured unknown


spdma501:# cfgadm -c configure c3
Nov 16 17:32:25 spdma501 last message repeated 54 times
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,48 (ssd2):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,47 (ssd3):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,46 (ssd4):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,45 (ssd5):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,44 (ssd6):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,43 (ssd7):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,42 (ssd8):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,41 (ssd9):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,40 (ssd10):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,3f (ssd11):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,3e (ssd12):
Nov 16 17:32:26 spdma501 corrupt label - wrong magic number
Nov 16 17:32:26 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,3d (ssd13):

spdma501:# cfgadm -c configure c5
Nov 16 17:32:55 spdma501 last message repeated 5 times
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,48 (ssd14):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,47 (ssd15):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,46 (ssd16):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,45 (ssd17):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,44 (ssd18):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,43 (ssd19):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,42 (ssd20):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,41 (ssd21):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,40 (ssd22):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,3f (ssd23):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,3e (ssd24):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number
Nov 16 17:32:59 spdma501 scsi: WARNING: /pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,3d (ssd25):
Nov 16 17:32:59 spdma501 corrupt label - wrong magic number


spdma501:# format < /dev/null
Searching for disks...Nov 16 17:33:04 spdma501 last message repeated 1 time
Nov 16 17:33:07 spdma501 scsi: WARNING: /pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,48 (ssd2):
Nov 16 17:33:07 spdma501 corrupt label - wrong magic numberdone

c3t50060482CCAAE5A3d61: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d62: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d63: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d64: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d65: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d66: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d67: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d68: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d69: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d70: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d71: configured with capacity of 17.04GB
c3t50060482CCAAE5A3d72: configured with capacity of 17.04GB
c5t50060482CCAAE5BCd67: configured with capacity of 17.04GB
c5t50060482CCAAE5BCd68: configured with capacity of 17.04GB
c5t50060482CCAAE5BCd69: configured with capacity of 17.04GB
c5t50060482CCAAE5BCd70: configured with capacity of 17.04GB
c5t50060482CCAAE5BCd71: configured with capacity of 17.04GB
c5t50060482CCAAE5BCd72: configured with capacity of 17.04GB


AVAILABLE DISK SELECTIONS:
0. c1t0d0
/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w2100000c506b2fca,0
1. c1t1d0
/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w2100000c506b39cf,0
2. c3t50060482CCAAE5A3d61
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,3d
3. c3t50060482CCAAE5A3d62
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,3e
4. c3t50060482CCAAE5A3d63
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,3f
5. c3t50060482CCAAE5A3d64
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,40
6. c3t50060482CCAAE5A3d65
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,41
7. c3t50060482CCAAE5A3d66
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,42
8. c3t50060482CCAAE5A3d67
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,43
9. c3t50060482CCAAE5A3d68
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,44
10. c3t50060482CCAAE5A3d69
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,45
11. c3t50060482CCAAE5A3d70
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,46
12. c3t50060482CCAAE5A3d71
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,47
13. c3t50060482CCAAE5A3d72
/pci@8,700000/SUNW,qlc@2/fp@0,0/ssd@w50060482ccaae5a3,48
14. c5t50060482CCAAE5BCd67
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,43
15. c5t50060482CCAAE5BCd68
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,44
16. c5t50060482CCAAE5BCd69
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,45
17. c5t50060482CCAAE5BCd70
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,46
18. c5t50060482CCAAE5BCd71
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,47
19. c5t50060482CCAAE5BCd72
/pci@8,600000/SUNW,qlc@1/fp@0,0/ssd@w50060482ccaae5bc,48
Specify disk (enter its number):



IF YOU DON'T SEE THE NEW LUNS IN FORMAT, RUN devfsadm !!!!


# /usr/sbin/devfsadm



Label the new disks !!!!



# cd /tmp


# cat format.cmd
label
quit


# for disk in `format < /dev/null 2> /dev/null | grep "^c" | cut -d: -f1`
do
format -s -f /tmp/format.cmd $disk
echo "labeled $disk ....."
done
Posted by JAUGHN Labels: ,

0 comments:

Visit the Site
MARVEL and SPIDER-MAN: TM & 2007 Marvel Characters, Inc. Motion Picture © 2007 Columbia Pictures Industries, Inc. All Rights Reserved. 2007 Sony Pictures Digital Inc. All rights reserved. blogger template by blog forum